In 2019 Sonitx began a government contract with data reporting requirements.
A total of 18,802 coils were cleaned and analyzed for air flow both before and after cleaning. The results were documented.
During that time, the data gathered painted a clear picture of the cost of coil cleaning in the Las Vegas Climate.
The Cost of our service over a five year period was
ZERO dollars
with the energy savings.
The government was able to put money BACK in its budget because of our services.
MORE DATA FOR DATA NERDS LIKE US:
Here are the calculations used based on data provided from the cleaning over 18,000 coils, broken down to represent a 2000 square ft retail space:
First, let's take a look at the actual COST of running the typical HVAC unit in Las Vegas.
Generally, the smallest Rooftop Units we come across on commercial buildings are three tons. So for these calculations, we'll use a three-ton unit.
Reasonable assumptions for Las Vegas:
A 3-ton AC unit has a cooling capacity of 36,000 BTU/hour (1 ton = 12,000 BTU/hour). The SEER rating tells us how many BTUs of cooling the unit provides per watt-hour of electricity. Watts = BTU/h / SEER = 36,000 BTU/hour / 16 = 2,250 watts Kilowatts (kW) = Watts / 1000 = 2.25 kW
kWh per day = kW * hours per day = 2.25 kW * 12 hours = 27 kWh/day
kWh per month = kWh per day * 30.44 days/month = 27 kWh/day * 30.44 days/month = 821.88 kWh/month
kWh per cooling season = kWh per month * number of cooling months = 821.88 kWh/month * 9 months = 7396.92 kWh
Annual cost = kWh per cooling season * cost per kWh = 7396.92 kWh * $0.17/kWh = $1257.48
For a 2000 Square ft Retail Store, we assume a 5-ton system with an estimated annual cost of $2800 per year.
Providing a range for 4-ton to 6-ton systems:
With an average cost per year of $2800, the cost over 5 years is approximately $14,000 for a 2000 square ft retail space.
In our five-year study, the average decrease in airflow was 21%. A 21% airflow loss results in an increased electricity cost of $1468.50 over five years.
Baseline Cooling Cost (5 years): $2797.19/year * 5 years = $13,985.95
Evaporator Coil Cleaning Cost (once every 5 years): $500 (total for both units)
Condenser Coil Cleaning Cost (annually for 5 years): $20/year/unit * 2 units * 5 years = $200
Sonitx Filter Service Cost (Quarterly for 5 years): $112/year * 5 years = $560
Total Cost (Sonitx Service): Baseline energy + Evaporator cleaning + Condenser cleaning + Filter service: $13,985.95 + $500 + $200 + $560 = $15,245.95
Subtract the savings from NV Energy ($1,500): Your total cost over five years to run your HVAC system is $13,745.95, or $2749 per year, or $229 per month.
The end result, according to the measured data, is that using our full services contract costs you nothing.
The $21 per month you are already giving to NVEnergy, can be converted to a full service airflow contract for a total cost of zero.
Larger facilities fare even better.
If your electric bill is over $230/mo you've save even more.
Contact us to find out what we can do for you.
Copyright © 2025 Sonitx West - All Rights Reserved.
We use cookies to analyze website traffic and optimize your website experience. By accepting our use of cookies, your data will be aggregated with all other user data.